MAKLUMAT BAHAN/BARANGAN YANG DILULUSKAN

Keterangan Barangan : COMBINED OVERCURRENT AND EARTH FAULT RELAY
Kod Barangan : EE031201.ME152.A260
Nama Syarikat : MUN HEAN (MALAYSIA) SDN. BHD.
Status Syarikat : PEMBEKAL
Alamat : NO. 15, JALAN SS 26/6 TAMAN MAYANG JAYA
47301 PETALING JAYA SELANGOR
No. Telefon : 0378042288
No. Fax : 03-78043307
Jenama : MH
No. Laporan : i) LAPORAN UJIAN TUV (ENVIRONMENTAL) : 7191242232-EEC20/02-LYA; ii) LAPORAN UJIAN TUV (SAFETY) : 7191242232-EEC20/04; iii) LAPORAN UJIAN TUV (EMC) : 7191242232-EEC20/01
Tarikh Tamat : 15-02-2025
Rujukan : i) ENVIRONMENTAL STANDARDS : IEC 60255-22-1:1988 & IEC 60255-21-2:1988; ii) SAFETY STANDARD : IEC 60255-27:2013 (CLAUSE 10.6.1.6 CYCLIC TEMPERATURE, CLAUSE 10.6.4.2 IMPULSE VOLTAGE, CLAUSE 10.6.4.3 AC/DC DIELECTRIC VOLTAGE, CLAUSE 10.6.4.4 INSULATION RESISTANCE & CLAUSE 10.6.5.3 THERMAL SHORT TIME); iii) EMC STANDARD : IEC 60255-26:2013
Catatan : i) COMMUNICATION INTERFACE : RS 485; ii) COMMUNICATION PROTOCOL : MODBUS RTU; iii) COMMUNICATION DEVICE : PERSONAL COMPUTER; iv) REMOTE REAL TIME MONITORING AND MANAGEMENT SYSTEM : YES; v) AMBIENT TEMPERATURE : -10 °C TO 55 °C; vi) RELATIVE HUMIDITY : < 93%; vii) DEGREE OF PROTECTION : IP 31 AT PANEL; viii) FAULT RECORD : YES; ix) BUILT-IN SELF-TEST/DIAGNOSTIC : NO; x) EXTERNAL ALARM CONTACT FOR PROTECTION RELAY FAILURE/DEFECT : NO; xi) OTHER(S) : MECHANICAL TRIP BUTTON (ANSI 86 COMPLIANCE)
Negara : Singapura


BilMODELPOWER SUPPLYKETERANGAN BAHAN/BARANGANTIME DELAY SETTING RANGESCURRENT SETTING RANGES
1REA 200n85 ~ 265 VAC/VDCOVER CURRENT PROTECTION & EARTH FAULT PROTECTION (OVER CURRENT PROTECTION) a) LOW SET TIME DELAY SETTING: i) TMS FOR INVERSE TIME DELAY: 0.03 TO 2 (IEC, 1.3/10) 0.3 TO 20 (ANSI, IAC) ii) DELAY FOR DEFINITE TIME: 0.03 s TO 2 s ________________________________ b) HIGH SET TIME DELAY SETTING: i) DELAY FOR DEFINITE TIME: 0 s (INSTANTANEOUS) a) LOW SET OVER CURRENT SETTING: 20% TO 200% OF In ____________________ b) HIGH SET OVER CURRENT SETTING: 2 TO 10 OF LOW SET OVER CURRENT SETTING
2REA 200n85 ~ 265 VAC/VDCOVER CURRENT PROTECTION & EARTH FAULT PROTECTION (EARTH FAULT PROTECTION) a) LOW SET TIME DELAY SETTING: i) TMS FOR INVERSE TIME DELAY: 0.03 TO 2 (IEC, 1.3/10) 0.3 TO 20 (ANSI, IAC) ii) DELAY FOR DEFINITE TIME: 0.03 s TO 2 s ________________________________ b) HIGH SET TIME DELAY SETTING: i) DELAY FOR DEFINITE TIME: 0 s (INSTANTANEOUS)a) LOW SET EARTH FAULT SETTING: 2% TO 50% OF In ____________________ b) HIGH SET EARTH FAULT SETTING: 2 TO 10 OF LOW SET EARTH FAULT SETTING